beautypg.com

Clock/timer routing, Switches, Stand-alone-mode, sw1-1 – Texas Instruments SLAU081 User Manual

Page 15: 3 switches

background image

Switches

2-6

2.2.7

Clock/Timer Routing

A variety of options are available to the user. Be careful about altering these.

Clock/Timer Routing

Reference

Designator

Functional Description

W21

This jumper defines the clock that the ADC and DAC use for all their timing. The user can select
either the output from W23 or the output from W22 to be the base clock for the system.

W23

This jumper allows the user to select either an external clock, or the onboard 20-MHz oscillator for
conversion. In addition, this signal is fed to W20.

W20

W20 provides a route for the EVM to generate CLKS for a DSP if so desired.

W22

This jumper enables the user to select either the transmit clock from a DSP, or the output
from W24.

W24

W24 connects or isolates the timer output from a DSP.

2.3

Switches

There are three switches present on the EVM:

-

One 8-pin DIL switch which houses four individual switches; these are
denoted SW1-1, SW1-2, SW1-3, and SW1-4.

-

Two momentary push-button switches

Features and functions of each switch:

Reference

Designator

Function

Default

Condition

SW1-1

Selects either stand-alone mode (SAM) or user mode

SAM

SW1-2

Reserved

SW1-3

Reserved

SW1-4

Reserved

2.3.1

Stand-Alone-Mode, SW1-1

SW1-1 chooses either stand-alone mode or user mode. If the switch is set to
the off position, SAM is selected and the EVM ignores all signals generated
by a DSP. In addition, the EVM will not output any signals to a DSP or
microprocessor.

In this mode, SW2 and SW3 are used to reset the EVM’s logic and initiate
automatic conversions from the ADC, in addition to automatically routing the
serial bit stream from the ADC to the DAC for reconstruction.

Reference

Designator

Function

SW2

Initiates ADC and DAC conversions in SAM

SW3

Forces the EVM’s control logic into a known state