PTM 2-76
B070/B071
SP1902 004 (Web Near End) can be adjusted to change the near-end period. The
defaults for and amount of web that remains for copying are different for NA and
EUR/A.
Near-End
Area Near-End Web
Remaining
NA 90% 600K
EUR/A 86%
350K
The table below, provided for your reference, shows approximately how adjustment of
SP1902 002 affects the near-end and end displays on the B070 (90 cpm) or B071
(105 cpm).
Note that adjustment of SP1902 002 also affects SP1902 005 (Web Motor Control –
Web Motor Drive Interval (Low Speed)).
SP1902 002
*1
B070 B071 Low
Speed
Mode
*2
SP1902 004
*3
Near-End
Display
(Sheets)
*4
End Display
(Sheets)
Comments
20.7 s
17.0 s
25.3 s
90%
600K
670K
NA Default
15.6 s
12.8 s
19.0 s
90%
450K
500K
12.1 s
10.0 s
14.8 s
90%
350K
385K
10.4 s
8.5 s
12.7 s
90%
300K
330K
6.9 s
5.7 s
8.5 s
90%
200K
220K
12.6 s
10.4 s
15.4 s
86%
350K
410K
EUR/A Default
10.8 s
9.0 s
13.2 s
86%
300K
350K
7.2 s
6.0 s
8.8 s
86%
200K
230K
*1
: SP1902 002 (Web Motor Control – Web Motor Drive Interval)
*2
: SP1902 005 (Web Motor Control – Web Motor Drive Interval (Low Speed))
*3
: SP1902 004 (Web Motor Control – Web Near End Setting)
*4
: Calculated based on A4 LEF at 100% magnification.
NOTE: SP1902 003 (Web Motor Control – Web Near End Setting) not adjusted.