beautypg.com

Toshiba IK-TF2 User Manual

Page 18

background image

- 18 -

****1*

**

*3*

**

*3**** Changing each setting in 2PULSE mode






VShutter mode MANUAL, SS, EXT TRIG

--

1

SHUTTER --

VEXT TRIG mode

MODE

EXT TRIG

1PULSE SNR, 1PULSE SR, 2PULSE

EXT TRIG

2PULSE

TRIG PULSE

VInput trigger pulse setting at 2PULSE

FLD

'

FRM

FLD

ļ The rising edge

ļ The falling edge

ļ F

ront and back edges of pulse

V FLD/FRM SW FLD, FRM



< MODE = EXT TRIG EXT TRIG = 2PULSE>

Move up and down
By pushing
MENU UP,DOWN

Set by pushing
DATA UP,DOWN

(a) Changing inputting trigger pulse setting

Set the “

” to TRIG PULSE by pushing [MENU UP], [MENU DOWN] buttons.

Select either , or by pushing [DATA UP], [DATA DOWN] buttons.

* This setting is only valid in the 2PULSE mode. To make the trigger pulse setting when using the

1PULSE mode, first set the EXT TRIG mode to 1PULSE SNR or 1PULSE SR, then make the settings

with the TRIG PULSE items.

(b) Changing the CCD storage mode

Set the “

” to FLD/FRM by pushing [MENU UP], [MENU DOWN] buttons.

Select either FLD (field) or FRM (frame) by pushing [DATA UP], [DATA DOWN] buttons.