****1*
**
*3*
**
*3**** Changing each setting in 2PULSE mode
VShutter mode MANUAL, SS, EXT TRIG
--
1
SHUTTER --
VEXT TRIG mode
MODE
EXT TRIG
1PULSE SNR, 1PULSE SR, 2PULSE
EXT TRIG
2PULSE
TRIG PULSE
VInput trigger pulse setting at 2PULSE
FLD
'
FRM
FLD
ļ The rising edge
ļ The falling edge
ļ F
ront and back edges of pulse
V FLD/FRM SW FLD, FRM
< MODE = EXT TRIG EXT TRIG = 2PULSE>
Move up and down
By pushing
MENU UP,DOWN
Set by pushing
DATA UP,DOWN
(a) Changing inputting trigger pulse setting
Set the “
” to TRIG PULSE by pushing [MENU UP], [MENU DOWN] buttons.
Select either , or by pushing [DATA UP], [DATA DOWN] buttons.
* This setting is only valid in the 2PULSE mode. To make the trigger pulse setting when using the
1PULSE mode, first set the EXT TRIG mode to 1PULSE SNR or 1PULSE SR, then make the settings
with the TRIG PULSE items.
(b) Changing the CCD storage mode
Set the “
” to FLD/FRM by pushing [MENU UP], [MENU DOWN] buttons.
Select either FLD (field) or FRM (frame) by pushing [DATA UP], [DATA DOWN] buttons.