TOA Electronics D-901 User Manual
Page 86

86
[Auto-Leveler Settings]
Setting Item
Setting Range
Target Level
–20 to +10 dB (0 dB), 1 dB steps
Maximum Gain
0 to +20 dB (+6 dB), 1 dB steps
Attack Time
10, 20, 50, 70, 100, 120, 150, 200,250, 300, 500, 700 ms,
1, 1.2, 1.5, 2, 2.5, 3, 5, 7, 10 s
Release Time
100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 1.2, 1.5, 2, 2.5, 3, 5, 7, 10 s
[Gate Settings]
Setting Item
Setting Range
Threshold Level
–50 to +20 dB (–40 dB), 1 dB steps
Hysteresis
0 to +10 dB, 1 dB steps
Depth
–
∞ to 0 dB (–20 dB), 1 dB steps
Hold Time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
Attack Time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
Release Time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
ON/OFF
ON, OFF
[Level Sense Settings]
Setting Item
Setting Range
Attack Time
0.2, 0.5, 0.7, 1.0, 1.5, 2, 3, 5, 7, 10, 20, 50, 70, 100, 120, 150, 200,
250, 300, 500, 700 ms
1, 2, 3, 5 s
Release Time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5 s
[Auto-Mixing Group Settings]
Setting Item
Setting Range
Auto-Mixing Group
GROUP A, GROUP B, GROUP C, GROUP D
[Ducker Settings]
Setting Item
Setting Range
Priority Level
1 – 8 (in order of the priority level from high to low)
Depth
–
∞ to 0 dB (–20 dB), 1 dB steps
Attack Time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
Release Time
10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
ON/OFF
ON, OFF
[NOM Attenuation Settings]
Setting Item
Setting Range
Attenuation Gain
0 log
10
NOM – 20 log
10
NOM (10)
ON/OFF