Delay time settings – TOA Electronics D-901 User Manual
Page 51
51
9.5.3. Attack time settings
[ O U T 1 ] C O M P
A T T A C K 1 0 . 0 m s
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the attack time.
Parameter setting range: 0.2 ms – 5 s (Refer to p. 85 for more
information.)
• Pressing an Output channel selector key permits the compressor
attack time to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.
9.5.4. Release time settings
[ O U T 1 ] C O M P
R E L E A S E
5 0 0 m s
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the release time.
Parameter setting range: 10 ms – 5 s (Refer to p. 85 for more
information.)
• Pressing an Output channel selector key permits the compressor
release time to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.
9.5.5. Makeup gain settings
[ O U T 1 ] C O M P
G A I N
+ 0 d B
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the makeup gain.
Parameter setting range: –INF (–
∞) to +10 dB in 1 dB steps.
• Pressing an Output channel selector key permits the
compression makeup gain to be set for that channel. The [OUT 1]
indication changes to the selected channel number indication.
9.6. Delay Time Settings
[ O U T 1 ] D E L A Y
O F F
0 . 0 0 0 m s
ON
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the delay time.
Parameter setting range: 0 – 682.6 ms in 0.021 ms steps
• Press the function ON/OFF key to enable or disable the delay
function.
• Pressing an Output channel selector key permits the delay time
to be set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
• The setting screen reverts to the Input/Output Gain Setting
screen when the
shift key is pressed.
Compressor settings
(previous page)