12.5.2. Function assignment to the output contact
The following functions can be assigned to output contacts (1 – 8 when the D-981 or D984-VC is used, and 1
– 16 when the D-983 is used).
Preset memory recall tally, Channel ON/OFF tally, Contact input status tally,
and Line (stereo) input selection tally
The procedures for assigning functions are the same as those used when assigning functions to the input
contacts.
[Screen display operations]
Contact input
status tally
Preset memory
recall tally
Channel ON/OFF tally
Channel number
Preset memory number
Normally break
Normally make
Contact input number
[ U T Y ] R M I N
2 : N O N E
[ U T Y ] R M I N
8 : N O N E
Line (stereo) input
selection tally
Setting items are the same as above.
Setting items are the same as above.
[ U T Y ] R M O U T
1 : B R E A K
[ U T Y ] R M O U T
1 B R E A K
[ U T Y ] R M O U T
1 M A K E
[ U T Y ] R M O U T
1 P R E S E T 1
[ U T Y ] R M O U T
1 C H I N 1
[ U T Y ] R M O U T
1 R M I N 1
[ U T Y ] R M O U T
1 L i n e S e l S 2 – 1
[ U T Y ] R M O U T
1 : P R E S E T 1
[ U T Y ] R M O U T
1 : C H I N 1
[ U T Y ] R M O U T
1 : R M I N 1
[ U T Y ] R M O U T
1 : L i n e S e l S 2 – 1
Output contact
number selection
Input contact number selection (p. 65)
Protect settings (next page)
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
PARAMETER
PUSH-ENTER
CHANGE
Slot number/line (stereo)
input number
Set to [Normally break]*.
Set to [Normally make]*.
Select the preset memory
number.
Select the channel number.
Select the contact input number.
Select the slot number and line
(stereo) input number for the D-
936R or the D-937SP (only when
the D-936R or the D-937SP is
used).
(Example. S2-1: First line
(stereo) input for the stereo
module inserted into Slot 2)
* Normally break: Turning on the power sets the contact output to "break."
Normally make: Turning on the power sets the contact output to "make."
Note: All contact outputs are at break while the power is off.