HIGH DISCHARGE TEMPERATURE AND/OR HIGH FLUID TEMPERATURE
PROBABLE CAUSE
CORRECTION
Cabinet panels removed
Replace all panels, ensure all sealing surfaces and materials
are satisfactory.
Cooling water temperature is too
high
Check and adjust as necessary.
Cooling radiator is dirty
Clean to ensure adequate air flow across fins.
Low fluid level
Add fluid to required level on reservoir
Operating pressure is too high
Rotary screw pumps are designed to operate in the 10" to
29.9" HgV range. Any operating pressure over 10" may
cause the pump to overheat.
Excessive pressure in exhaust line
Clear restrictions in exhaust line to ensure atmospheric
pressure at discharge.
FREQUENT AIR/FLUID SEPARATOR CLOGGING
PROBABLE CAUSE
CORRECTION
Faulty inlet filter or inadequate filter
for the environment
If faulty inlet filter elements, replace them.
Faulty fluid filter
Replace fluid filter element
Fluid breakdown
Correct in accordance with the instruction in “Fluid
Breakdown” section of the troubleshooting guide
Incorrect fluid separator element
Use genuine Quincy replacement elements only
Extreme operating conditions such
as high vacuum pump discharge
temperatures, high ambient
temperature and high reservoir
pressure
Operate vacuum pump at recommended reservoir pressure
and air discharge temperature
Fluid contamination
Change fluid. Service inlet filter element and fluid filter
promptly in accordance with the recommended maintenance
schedule.
Too high fluid level in reservoir
Bring fluid level to recommended level by draining the
reservoir. Use the fluid level gauge as a guide.