Quincy Compressor 50093-103 User Manual
Page 64

58
POOR PUMPING SPEED (Capacity)
PROBABLE CAUSE
CORRECTION
Clogged inlet filter
Replace inlet filter element.
Intake line is narrow or contains
restrictions or debris
Re-plumb sections of line that are narrow or sections with
sharp turns. Maintain pump inlet diameter as far into the
process as possible. Check for obstructions in plumbing.
Problem in lubrication system
Check for adequate fluid flow rate and for restrictions in
fluid piping.
Excessive back pressure/separator
clogged
Replace separator element-keep exhaust at atmospheric
pressure.
Low fluid level
Fill fluid reservoir to proper level.
Condensation or contamination in
fluid
Replace pump fluid.
Pump is cold
Allow adequate warm-up time for pump to reach operating
temperature.
Shaft seal leak
Replace shaft seal.
Leak
Leak check system and compare to original rate of rise
pressure test. Look for damaged gaskets and leaks in
check/isolation valves. Check for leaks in inlet valve, and
piping to airend.
Vapor load being generated
Possible leak in water cooling jacket or water piping in
vacuum system. Leak check.
Materials of construction
Materials not compatible with vacuum service. Observe all
vacuum engineering conventions.
Temperature of system or process
gas increasing
Increases in temperature translate into ACFM load. Keep
temperatures constant.
Inlet valve not opening fully
Correct the situation in accordance with the instructions in
"Inlet Valve Not Opening or Closing in Relation to
Demand" section of the troubleshooting guide.