25. Scanner Timeout (Trigger Enabled Mode only)

These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period after

the trigger pulse is received. The Time-out period is the same whether the scanner is operating in Single,

Multiple or Continuous Read mode.

Page 48

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

,Z7,

Y0

Trigger remains ON

as long as trigger is pulled

(hardware trigger only)

,Y0,

Y1

1 Second after triggering

,Y1,

Y2

2 Seconds after triggering

,Y2,

Y3

3 Seconds after triggering

,Y3,

Y4

4 Seconds after triggering

,Y4,

Y5

6 Seconds after triggering

,Y5,

Y6

8 Seconds after triggering

,Y6,

Y7

10 Seconds after triggering

,Y7,