10. Fixing the Number of Digits

To avoid truncation errors, the scanner can be programmed to only decode bar codes of one specific length, i.e.,

containing a specific number of digits. It is also possible to program the scanner to only decode bar codes of

either of two specific

*

lengths.

“Fixing the Number of Digits” can only be applied to Code 39, Codabar, 2 or 5 and MSI/Plessey (UPC, Code

93 and Code 128 are not affected).

Page 31

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

,Z7,

(H0)

Disable fixation

,H0, B

(H1)

Enable fixation

,H1,

H2

Disable 1 character

Code 39 and Codabar (NW-7);

Disable 2 characters 2 of 5

,H2,

B

H3

Enable 1 character

Code 39 and Codabar (NW-7);

Enable 2 characters 2 of 5

,H3,

To fix one (1) length (or number of digits) of

bar code:

1. Scan “START” to enter the program-

ming mode

2. Scan “Enable fixation” bar code

3. Scan a sample bar code of the desired

length

4. Repeat Step #3, re-scanning the

sample bar code

5. Scan “STOP” to exit the programming

To fix two (2) different lengths of bar codes:

1. Scan “START” to enter the program-

ming mode

2. Scan “Enable fixation” bar code

3. Scan a sample bar code of the desired

length #1

4. Scan a sample bar code of the desired

length #2

5. Scan “STOP” to exit the programming

mode