Series NFT-1121/2135 Mini CCD Fixed Position Scanners

6. Options for Code 39

43 Data digits are available: 0 to 9, A to Z (caps only) plus . - $ / + % and space. If a check digit is

present, it will appear as part of the data.

If the scanner is programmed to calculate the check digit, and the bar code is not printed with a check

digit, the bar code will not read.

Another option available for Code 39 is to enable the reading of a single character bar code. See the

section on Fixing the Digit for this option.

Page 26

Computer

Command

Function

/Description

Bar Code

Command

(Z7)

START/END

Programming Menu

,Z7,

H4

Enable 1 character (3 characters

including start/stop characters)

,H4,

H2

Disable 1 character Code 39 and

Codabar (NW-7); Disable 2

characters 2 of 5

,H2,

C0

Disable check digit calculation

,C0,

B

C1

Enable check digit calculation

,C1,

C2

Transmit check digit

,C2,

C3

Do not transmit check digit

,C3,

D0

Do not transmit start/stop

characters (*……*)

,D0,

D1

Transmit start/stop characters

(*……*)

,D1,

B