RESET FEATURE

This dive computer is configured with a RESET feature that allows data to be cleared,
including Nitrogen and Oxygen calculations, FO2 set point, Log Mode entries, and
Download data.

WARNING: Reset after a dive and subsequent use for a repetitive dive conducted

by the same diver could result in serious injury to or death.

RESET PROCEDURE

• While in SURFACE MODE (new activation period or greater than a 10 minute post

dive surface interval), press the Left (Advance) button one (1) time to access PLAN
MODE.

• While 30 feet (or 9 meters) is displayed in the PLAN MODE, press and hold Both

buttons until SET 2 appears, then release the buttons.

• Press and release the Left (Advance) button to display the first 2 digits of the assigned

KEY CODE, flashing as 00.

• Press and release the Right (Select) button to increase the digits to 01.
• Press and release the Left (Advance) button again to display the second 2 digits of the

KEY CODE, flashing as 00.

• Press and release the Right (Select) button to increase the digits to 01.
• Press and release the Left (Advance) button to complete the RESET operation and turn

the unit OFF.