ATR

O

2

N

2

PC INTERFACE
PC Interface is not a setting, it is included in the Set 1 menu
for easy access when data in the unit's memory is to be
downloaded (copied) to the PC download software program
for storage and viewing.

To download data (while in the Surface Mode)-

• Press Both buttons simultaneously, release when SET: 1

appears (2 seconds).

• Press and release the Left (Advance) button, FO2 ap-

pears with the set point value flashing.

• Press the Left (Advance) button 3 more times.

• The graphic PC appears with a 120 second countdown

timer (Fig. 23). Download must be initiated before the
timer reaches 00 (within 2 minutes).

• Download is initiated by the external device requesting

data transfer (i.e., the PC download program).

• The unit reverts to Surface Mode after completion of the

Download operation, or after 2 minutes if neither button
is pressed.

Fig. 23 - PC Interface