Regency P48-1 Zero Clearance Direct Vent Gas Fireplace

17

INSTALLATION

Vertical Venting with Three (3) 90

o

Elbows

Option V

H + H1

V + V1

A)

2' Min.

3' Max.

4' Min.

B)

3' Min.

4' Max.

6' Min.

C)

4' Min.

5' Max.

7' Min.

D)

5' Min.

6' Max.

8' Min.

E)

6' Min.

7' Max.

9' Min.

F)

7' Min.

8' Max.

10' Min.

With these options, max. to-
tal pipe length is 30 feet with
min. of 10 feet total vertical
and max. 8 feet total horizon-
tal.
Please note min. 1 foot
between 90

o

elbows is re-

quired.

Vertical Venting with Three (3) 90

o

Elbows

Option

H

V

H + H1 V + V1

A)

1' Max.

1' Min.

3' Max.

3' Min.

B)

2' Max.

2' Min.

4' Max.

5' Min.

C)

3' Max.

3' Min.'

5' Max.

7' Min.

D)

4' Max.

4' Min.

6' Max.

9' Min.

E)

5' Max.

5' Min.

7' Max.

11' Min.

With these options, max. total
pipe length is 30 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 foot
between 90

o

elbows is re-

quired.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.