beautypg.com

Installation – Regency P48-1 User Manual

Page 15

background image

Regency P48-1 Zero Clearance Direct Vent Gas Fireplace

15

INSTALLATION

Horizontal Venting with Two (2) 90

o

Elbows

Option V

H + H1

A)

1' Min. 3' Max.

B)

2' Min. 4' Max.

C)

3' Min. 5' Max.

D)

4' Min. 6' Max.

E)

5' Min. 7' Max.

F)

6' Min. 8' Max.

Horizontal Venting with Two (2) 90

o

Elbows

Option H

V

H + H1

A)

1' Max.

1' Min. 3' Max.

B)

2' Max.

2' Min. 5' Max.

C)

3' Max.

4' Min. 6' Max.

D)

4' Max.

6' Min. 7' Max.

E)

5' Max.

8' Min. 8' Max.

Horizontal Venting with Three (3) 90

o

Elbows

Option H

V

H + H1 + H2

A)

1 Max. 1' Min.

3' Max.

B)

2' Max.

3' Min.

5' Max.

C)

3' Max.

5' Min.

6' Max.

D)

4' Max.

7' Min.

7' Max.

E)

5' Max.

9' Min.

8' Max.

F)

6' Max.

11' Min. 9' Max.

With these options, max.
total pipe length is 30
feet with min. of 11 feet
total vertical and max. 9
feet total horizontal.
Please note min.
1 foot between 90

o

elbows is required.

With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.

With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90

o

elbows

is required.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.