DIAGNOSTICS
The RP2100 Digital heater is equipped with on board
diagnostic controls. If there is a safety fault, a fault code
will be displayed along with a service indication.

NOTE: The digital temperature display may not coincide with the temperature reading of your pool or spa
thermometer. The RP2100 reads the water temperature at the inlet of the heater. Due to the circulation
characteristics of any pool or spa, the water temperature at the inlet to the heater may differ from that observed
at a given location in the pool or spa

.

If the PRS fault code is displayed, it indicates that
there is insufficient flow through the heater. Make sure
the pool filter and pump strainer are clean before calling
a service representative.

STATUS CODES
Display

Definition

CFH

Call for heat

CLK

Time clock

LOW

Caution - low water temperature

OFF

Off mode

REM

Remote control activated

SPK

Spark

SPR

Spare fault code indicator

FAULT CODES

Display

Definition

BD1

Board failure

FFL

Flame sensing when pilot and gas
valves are closed

HL1

Hi limit switch #1 open

HL2

Hi limit switch #2 open

IGN

Ignition control failure

ILO

Ignition lock out

PLT

Pilot failure

PRS

Pressure switch open

ROL

Heat roll-out safety switch open

SNS

Sensor failure

VNT

Vent switch open

PROGRAM MODES
Display

Definition

CCC

Celsius setting

F/C

Change from Fahrenheit to Celsius

FFF

Fahrenheit setting

RES

Reset defaults

SET

Set point max adjustment

READING A FAULT
The word “SERVICE” will flash on and off if the PC board
detects a known fault. The fault will be displayed in
three big letters on the lower left of the display.

SERVICE WILL FLASH

3 LETTER FAULT CODE

See table for fault definition

Fig# 9482

Fig# 9485