DIAGNOSTICS
The RP2100 Digital heater is equipped with on board
diagnostic controls. If there is a safety fault, a fault code
will be displayed along with a service indication.
NOTE: The digital temperature display may not coincide with the temperature reading of your pool or spa
thermometer. The RP2100 reads the water temperature at the inlet of the heater. Due to the circulation
characteristics of any pool or spa, the water temperature at the inlet to the heater may differ from that observed
at a given location in the pool or spa
.
If the PRS fault code is displayed, it indicates that
there is insufficient flow through the heater. Make sure
the pool filter and pump strainer are clean before calling
a service representative.
STATUS CODES
Display
Definition
CFH
Call for heat
CLK
Time clock
LOW
Caution - low water temperature
OFF
Off mode
REM
Remote control activated
SPK
Spark
SPR
Spare fault code indicator
FAULT CODES
Display
Definition
BD1
Board failure
FFL
Flame sensing when pilot and gas
valves are closed
HL1
Hi limit switch #1 open
HL2
Hi limit switch #2 open
IGN
Ignition control failure
ILO
Ignition lock out
PLT
Pilot failure
PRS
Pressure switch open
ROL
Heat roll-out safety switch open
SNS
Sensor failure
VNT
Vent switch open
PROGRAM MODES
Display
Definition
CCC
Celsius setting
F/C
Change from Fahrenheit to Celsius
FFF
Fahrenheit setting
RES
Reset defaults
SET
Set point max adjustment
READING A FAULT
The word “SERVICE” will flash on and off if the PC board
detects a known fault. The fault will be displayed in
three big letters on the lower left of the display.
SERVICE WILL FLASH
3 LETTER FAULT CODE
See table for fault definition
Fig# 9482
Fig# 9485