Section 5 Specifications of a Config File

Rev. 1.01 Mar. 17, 2008 Page 43 of 128

REJ10J1822-0101

5.6

Client Information

The following definitions of client information are available.

• CLNT_NOINIT;

The client-initialization function is not to be created.

• CLNT_NOSHUTDOWN;

The client-shutdown function is not to be created.

• CLNT_CALLCHK;

Facilitates saving the return value in RPC calls

• CLNT_SECTION{…};

Section name to be given to the client stub

5.6.1

CLNT_NOINIT

Format:

CLNT_NOINIT;

Description:

RPCGEN creates the following client-initialization function in _clnt.c as the
standard:

INT32 rpcclnt__init(UINT32 __ulRPCServerID, UINT32

__ulRPCServerVersion );

If the CLNT_NOINIT statement is present, RPCGEN will not create the client-initialization
function. Use CLNT_NOINIT when the client-initialization function is provided as part of the
application. Also refer to section 8.6, Client-Initialization Function.

Example:

CLNT_NOINIT;