Section 8 Application Interface

Rev. 1.01 Mar. 17, 2008 Page 101 of 128

REJ10J1822-0101

8.7

Client-Shutdown Function

The client-shutdown function is called by the client application and terminates the connection to
the server by using rpc_disconnect().

When CLNT_NOSHUTDOWN has not been specified, RPCGEN generates a client-shutdown
function rpcclnt__shutdown. RPCGEN outputs the client-shutdown function itself
to _clnt.c and the prototype declaration to _clnt.h.

refers to the server name defined with SVR_NAME.

When CLNT_NOSHUTDOWN has been specified, RPCGEN does not generate a client-shutdown
function. The client-shutdown function must be provided by the user if one is required.

The specification of the client-shutdown function generated by RPCGEN is as follows.

• C-language API

INT32 rpcclnt__shutdown(UINT32 __ulRPCServerID, UINT32

__ulRPCServerVersion);

• Return value

The return value of rpc_disconnect()

• Parameter: __ulRPCServerID and __ulRPCServerVersion

These parameters indicate the server ID and server version, respectively. When SVR_AUTH
has not been specified, however, the server ID and server version are ignored. Instead, the
macros RPCSVR_ID_ and RPCSVR_VERS_ output to file>_public.h are taken as the server ID and server version in terminating a connection to the
server.

• Specification

Connection to the server is terminated by using rpc_disconnect() and no callback function is
specifiable for the client-shutdown function. In the current HI7200/MP specification,
rpc_disconnect() handles no processing other than terminating the connection to the server.