Pre l iminar y – Runco PL-61DHD User Manual
Page 21
Runco PlasmaWall Owner’s Operating Manual
11
PRE
L
IMINAR
Y
6.
COMPOSITE VIDEO INPUT
Standard composite video input for connecting a VCR, camcorder, laser disc player
or other composite video source.
7.
S-VIDEO 1 / S-VIDEO 2
Two, standard S-Video inputs for connecting a DVD player, satellite receiver or Super
VHS (S-VHS) VCR.
8.
12-VOLT (800 mA) TRIGGER OUTPUTS
Connection for up to three (3), 12-volt trigger-controlled devices.
9.
RS-232 OUTPUT (6-Wire, RJ-11 jack)
Connect this to the EXTERNAL CONTROL input of the PlasmaWall.
10. IR
Wired input from an external remote control or infrared receiver. It is a 3.5-mm, mini
phono jack, wired as follows:
Ring = +5V
Tip = IR Input
Sleeve = Ground
11. RS-232 CONTROL PORT
A female, 9-pin D-sub connector for interfacing with a PC or home theater
automation/control system.
12. POWER INPUT (100 to 240 VAC)
Connect the DHD Controller to power here.
13. MAIN AC FUSE
This is the main AC input fuse (5mm x 20mm, 500 mA, 250V slow-blow).
14. MAIN POWER SWITCH
Disconnects or applies power to the DHD Controller.
When an external remote control or infrared receiver is connected
to the wired IR input, the IR sensor on the front of the DHD
Controller is disabled.
Note