Technical details – Rinnai 26i User Manual
Page 12
12
TECHNICAL DETAILS
* Factory Setting
** Minimum operation flow based on temperature setpoint and inlet
conditions.
Infinity Model
Infinity 26i
HD50i
Units
Installation Internal
Internal
Nat Gas Press Low
1.9
1.9
mbar
Nat Gas Press High
8.5
8.5
mbar
LPG Press Low
2.3
2.3
mbar
LPG Press High
10.8
10.8
mbar
Height 600
600
mm
Width 350
350
mm
Depth 224
224
mm
Weight 22
22
kg
Flue System
Direct Forced Vent
Temp. Range Controllers
37C - 55C
37C - 65C
deg C
Ignition
Gas Consumption Low
Nat Gas
4.4
4.4
kW
LPG 4.4
4.4
kW
Gas Consumption High
Nat Gas
54
54
kW
LPG 54
54
kW
Max Flow raised 33C
19.6
19.6
L/min
Min Operation Flow
2.4**
L/min
Water Pressure Nom.
1.4 - 8.3
bar
Power Supply
230 V / 50 Hz
Electric Consumption
80
80
Watts
Direct Electronic Ignition
Temp. Range without
Controllers
40,43,50,55*,
60,65,75
40,43,50,55,
60,65*,75,85
deg C