SECTION 2: INSTALLER RESPONSIBILITY
The installer is responsible for the following:

• To install the pump and electrical supplies, in

accordance with applicable specifications and
codes. Roberts-Gordon recommends the installer
contact a local building inspector or Fire Marshal
for guidance.

• To use the information given in a layout drawing

and in the manual together with the cited codes
and regulations to perform the installation.

• To furnish all needed materials not furnished as

standard equipment.

• To plan location of supports.

• To provide access to pump for servicing on all

sides and for pump removal.

• To provide the owner with a copy of this installa-

tion, operation and service manual.

• To never use pump or pump platform as support

for ladder or other access equipment and never
hang or suspend anything from pump or pump
platform.

• To safely and adequately install pump using

materials with a minimal working load of 400 lb
(181 kg).

2.1 Corrosive Chemicals

Roberts-Gordon cannot be responsible for ensuring
that all appropriate safety measures are undertaken
prior to installation; this is entirely the responsibility
of the installer. It is essential that the contractor, the
sub-contractor, or the owner identifies the presence
of combustible materials, corrosive chemicals or
halogenated hydrocarbons* anywhere in the
premises.

* Halogenated Hydrocarbons are a family of chemical com-

pounds characterized by the presence of halogen elements (flu-

orine, chlorine, bromine, etc.). These compounds are

frequently used in refrigerants, cleaning agents, solvents, etc. If

these compounds enter the air supply of the burner, the life span

of the heater components will be greatly reduced. An outside air

supply must be provided to the burners whenever the presence

of these compounds is suspected. Warranty will be invalid if the

heater is exposed to halogenated hydrocarbons.

2.2 National Standards and Applicable Codes

All Appliances must be installed in accordance with
the latest revision of the applicable standards and
national codes. This refers also to the electric, gas
and venting installation. Note: Additional standards
for installations in Public Garages, Aircraft Hangars,
etc. may be applicable.

SECTION 3: UNPACKING THE PUMP
3.1 Open Shipping Cartons

Open cartons and remove packing inserts. Carefully
remove pump components from the cartons. Lift
assembly by gripping metal pump frame. Two people
are required (weight 112 lb, 51 kg). This pump has
been tested prior to packing. The impeller was
dynamically balanced before assembly and requires
care in handling to avoid damage.

CAUTION

Do not use heater and pump in an area containing

corrosive chemicals.
Avoid the use of corrosive chemicals to ensure a

longer life of the pump, burner, tubing and other

parts.
Failure to follow these instructions can result in

property damage.

WARNING

Severe Injury Hazard

Install pump scroll and inlet assembly before operating

high speed rotating impeller.

Keep hands, fingers and clothing away from inlet and

outlet.

Install and operate equipment according to installation

manual.

Failure to follow these instructions can result in death

or severe injury.