INSTALLER

INSTALLATION MENU

Macro Editor (cont’d)

i. LEARNED SRC –

Select the learned source bank to be assigned to the source

(LnSrc)

component. Procedure advances to KEY FUNCTION (step 6)

b. Selected: Unassigned

Selected command and subsequent commands are cleared.

(Unasg)

Procedure advances to COMMAND NUM (step 3)

c. Selected: Default

Default selects the same device type and device code previously

(Deflt)

setup in BASIC SETUP. Procedure advances to KEY FUNCTION
(step 6)

d. Selected: Macro:

i. MACRO -

A macro can “call” another macro if a sequence of more than 10

(Macro)

commands is needed.

ii. MACRO ID

Enter the macro ID number. Menu advances to COMMAND NUM

(MacID)

(step 3)

e. Selected: Delay

Enter a 1- to 60-second delay time to postpone delivery of the

(Delay)

next command in the macro. Procedure advances to COMMAND
NUM (step 3)

f. All Other Selections:

Procedure advances to DEVICE CODE (step 6)

5. DEVICE CODE –

Source component code for IR control.

(DevCd)

6. KEY FUNCTION –

Select a function (Play, etc.).

(KeyFn)

SYSTEM INFO (SInfo)

System Info allows the installer to view the controller’s manufacturing build properties.
See Installation Menu on Page 50 and System Info - Flow Chart on page 72

#CONTROLLERS (#Ctls)

BUILD TIME (BTime)

BUILD DATE (Bdate)

VERSION (Ver)

1. #CONTROLLERS -

Displays the number of CAV6.6 controllers in the system.

(#Ctls)

2. BUILD TIME -

Displays the Software Build Time of the controller.

(BTime)

3. BUILD DATE -

Displays the Software Build Date of the controller.

(BDate)

4. VERSION -

Displays the software version of the CAV6.6.

(Ver)

61