beautypg.com

Ricoh Monochrome PoCl Camera Link Camera FV-L030B1 User Manual

Page 31

background image



31/32

FV-L030B1
User’s Guide Rev. 1.01

Command No.

Command Descriptions

C5H: [7

0]

[Look-up table (Gamma)] Initial data: [7..0] = 00H

D[7..0]

D7

D6

D5

D4

D3

D2

D1

D0

D7 to D3:

No function

Always set as “00000”

D2:

Look-up table (RAM)

0: OFF

1: Load

D1:

Look-up table upload

0: RAM only

1: RAM and ROM

D0:

No function

Always set as “0”

F0H:[7

0]

[Signal selection for the I/O connector] Initial data: [7

0] = the value of 00H, data range: 0 to 15

Sets the signals of the I/O connector.

D[7..0]

D7

D6

D5

D4

D3

D2

D1

D0

D7 to D4:

No function

Always set as “0000”

D3~D0:

The signals of the /IO connector selection

0H: Option 0

1H: Option 1

2H: Option 2

3H: Option 3

4H: Option 4

5H: Option 5

6H: Option 6

7H to FH: No function

(Prohibited settings. Do not set these values)