beautypg.com

Raymarine ST8001 User Manual

Page 15

background image

Chapter 1: SmartPilot Operation

9

Note: The

RESPONSE screen is set as a default data page (see SmartPilot

Commissioning Guide) so you can also access it by pressing

disp and then

scrolling through the data pages.

2. Press the up or down arrow keysto change the response level.

3. Press disp or wait for 5 seconds to return to the previous display.

Adjusting performance – Non-G systems
Non-G SmartPilot systems have three different response levels:

Response Level 1: AutoSeastate on (Automatic deadband)

The SmartPilot will gradually ignore repetitive boat movements and
only react to true variations in course. This provides the best compro-
mise between power consumption and course keeping accuracy

Response Level 2: AutoSeastate off (Minimum deadband)

This setting provides tighter course keeping but will lead to increased
power consumption and drive unit activity

Response Level 3: AutoSeastate off + yaw damping

This setting provides the tightest possible course keeping by introducing
counter rudder yaw damping You can adjust the counter rudder setting in
Dealer Calibration (see SmartPilot Commissioning Guide)

To make a temporary change to the response setting:

1. Display the RESPONSE screen by pressing the resp key

2. Pressthe up arrow or down arrow keysto change the response between

levels 1 to 3.

3. Press disp or wait for 5 seconds to return to the previous display.

D5453-2

Increase

response

Decrease
response