(Input pin)

Specify one from { RAPI_AN0, RAPI_AN1, RAPI_AN2, RAPI_AN3, RAPI_AN4,

RAPI_AN5, RAPI_AN6, RAPI_AN7, RAPI_AN00, RAPI_AN01, RAPI_AN02,

RAPI_AN03, RAPI_AN04, RAPI_AN05, RAPI_AN06, RAPI_AN07, RAPI_AN20,

RAPI_AN21, RAPI_AN22, RAPI_AN23, RAPI_AN24, RAPI_AN25, RAPI_AN26,

RAPI_AN27, RAPI_INEX0, RAPI_ANEX1 }. The default is RAPI_AN0.

(Operating

frequency)

Specify one from { RAPI_FAD, RAPI_FAD2, RAPI_FAD3, RAPI_FAD4,

RAPI_FAD6, RAPI_FAD12 }. The default value is RAPI_FAD4.

(Resolution)

Specify one from { RAPI_10BIT, RAPI_8BIT }. The default value is

RAPI_8BIT.

(Operating

states set)

Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is

RAPI_AD_OFF.

(Conversion

method)

Specify one from { RAPI_WITH_SAMPLE_HOLD,

RAPI_WITHOUT_SAMPLE_HOLD }.

The default value is RAPI_WITHOUT_SAMPLE_HOLD.

(Trigger)

Specify one from { RAPI_SOFTWARE_TRIGGER,

RAPI_EXTERNAL_TRIGGER }.

The default value is RAPI_SOFTWARE_TRIGGER.

(External

Op-Amp

Connection)

Specify one from { RAPI_ANEX_UNUSED, RAPI_EXTERNAL_OP_AMP }.

The default value is RAPI_ANEX_UNUSED.

• Specifiable definition values when single sweep mode is used

(RAPI_SINGLE_SWEEP specified)

(Input pin)

Specify one from { RAPI_P0_GROUP, RAPI_P10_GROUP,

RAPI_P2_GROUP }. The default value is RAPI_P10_GROUP.

(Operating

frequency)

Specify one from { RAPI_FAD, RAPI_FAD2, RAPI_FAD3, RAPI_FAD4,

RAPI_FAD6, RAPI_FAD12 }. The default value is RAPI_FAD4.

(Resolution)

Specify one from { RAPI_10BIT, RAPI_8BIT }. The default value is

RAPI_8BIT.

(Operating

states set)

Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is

RAPI_AD_OFF.

(Conversion

method)

Specify one from { RAPI_WITH_SAMPLE_HOLD,

RAPI_WITHOUT_SAMPLE_HOLD }.

The default value is RAPI_WITHOUT_SAMPLE_HOLD.

(Trigger)

Specify one from { RAPI_SOFTWARE_TRIGGER,

RAPI_EXTERNAL_TRIGGER }.

The default value is RAPI_SOFTWARE_TRIGGER.

(External

Op-Amp

Connection)

Specify one from { RAPI_ANEX_UNUSED, RAPI_EXTERNAL_OP_AMP }.

The default value is RAPI_ANEX_UNUSED.

• Specifiable definition values when repeat sweep mode 0 is used

(RAPI_REPEAT_SWEEP0 specified)

(Input pin)

Specify one from { RAPI_P0_GROUP, RAPI_P10_GROUP,

RAPI_P2_GROUP }. The default value is RAPI_P10_GROUP.

(Operating

frequency)

Specify one from { RAPI_FAD, RAPI_FAD2, RAPI_FAD3, RAPI_FAD4,

RAPI_FAD6, RAPI_FAD12 }. The default value is RAPI_FAD4.

(Resolution)

Specify one from { RAPI_10BIT, RAPI_8BIT }. The default value is

RAPI_8BIT.