Basicreceivingstatusread – Renesas M16C/62P Group User Manual

Page 25

background image

Rev.1.00 2007.11.1
REC10B0002-0100

23

__BasicReceivingStatusRead

Synopsis

unsigned int __BasicReceivingStatusRead(unsigned long data)

data Setup

data

Description

Returns the receive status of serial communication.

[data]

For data, the following values can be set.

RAPI_COM1 UART0

RAPI_COM2 UART1

RAPI_COM3 UART2

RAPI_COM4 SI/O3

RAPI_COM5 SI/O4

Return value

The receive status of serial communication is returned. The returned value is one of

the following.

(UART0, UART1, UART2)

RAPI_RX_INCOMPLETE

Reception not complete yet.

Other than above

Reception complete. The value read from the UARTi receive

buffer register (i = 0 to 2).

(SI/O3,

SI/O4)

RAPI_RX_INCOMPLETE

Reception not complete yet.

Other than above

Reception complete. Low-order 8 bits: The value read from the

SI/Oi transmit/receive register (i = 3, 4).

Functionality

Serial I/O

Reference

__BasicStartSerialReceiving

,

__BasicStopSerialReceiving

Remark

If an undefined value is specified in the argument, operation of the API cannot be

guaranteed.

Program example

#include ”rapi_sif_m16c_62p”

void func( void )
{
unsigned int rcv_data;

..........
rcv_data = __BasicReceivingStatusRead( RAPI_COM1 );
..........
}