Dynamixel dx-116, 5. reset – Robotis DX-116 User Manual
Page 23
22
English Translation by: Tribotix Pty Ltd
www.tribotix.com
DYNAMIXEL
DX-116
Example 3
To obtain the status packet of a Dynamixel with ID=1
Instruction Packet : 0XFF 0XFF 0X01 0X02 0X01 0XFB`
ID LENGTH INSTRUCTION CHECKSUM
The returned Status Packet is as follow;
Status Packet : 0XFF 0XFF 0X01 0X02 0X00 0XFC
ID LENGTH ERROR CHECKSUM
4-5. RESET
Function
Restore the condition of the Control Table of the Dynamixel back to the Factory
Default values.
Length
0X02
Instruction
0X06
Parameter
NONE
Example 4
Reset Dynamixe with ID=0
Instruction Packet : 0XFF 0XFF 0X00 0X02 0X06 0XF7`
ID LENGTH INSTRUCTION CHECKSUM
The returned Status Packet is as follows;
Status Packet : 0XFF 0XFF 0X00 0X02 0X00 0XFD
ID LENGTH ERROR CHECKSUM
Please note that after a RESET instruction, the ID of the Dynamixel is changed
to 1.