beautypg.com

Dynamixel dx-116, 5. reset – Robotis DX-116 User Manual

Page 23

background image

22

English Translation by: Tribotix Pty Ltd

www.tribotix.com

DYNAMIXEL

DX-116

Example 3

To obtain the status packet of a Dynamixel with ID=1

Instruction Packet : 0XFF 0XFF 0X01 0X02 0X01 0XFB`

ID LENGTH INSTRUCTION CHECKSUM

The returned Status Packet is as follow;

Status Packet : 0XFF 0XFF 0X01 0X02 0X00 0XFC

ID LENGTH ERROR CHECKSUM

4-5. RESET

Function

Restore the condition of the Control Table of the Dynamixel back to the Factory

Default values.

Length

0X02

Instruction

0X06

Parameter

NONE

Example 4

Reset Dynamixe with ID=0

Instruction Packet : 0XFF 0XFF 0X00 0X02 0X06 0XF7`

ID LENGTH INSTRUCTION CHECKSUM

The returned Status Packet is as follows;

Status Packet : 0XFF 0XFF 0X00 0X02 0X00 0XFD

ID LENGTH ERROR CHECKSUM

Please note that after a RESET instruction, the ID of the Dynamixel is changed

to 1.