beautypg.com

Raypak 336A User Manual

Page 39

background image

39

PILOT REMOVAL AND CLEANING

1. Disconnect pilot tubing and wires from gas valve.
2. Remove pilot assembly from burner tray.
3. Remove pilot from bracket.
4. Remove pilot orifice and air opening (Honeywell

MV unit only), and clean with wire or small brush.

CAUTION!

Do not enlarge hole in pilot orifice.

5. Reverse above procedure to reinstall.

Pilot

Pilot

Air
Opening

Orifice

Orifice

Fig. # 8045.1

Fig. # 8102.0

HEAT EXCHANGER REMOVAL

1. Shut water, gas and electricity off, close valves and

relieve pressure, then remove relief valve. Remove
side inspection panels.

2. Remove top jacket holding screws.
3. Remove rear top panel.
4. Remove screws mounting the rain shield to the rear

panel. Also remove the screws that mount the rain
shield to the sway brace. Remove rain shield.

5. Remove the four (4) screws holding down the flue

collector. Remove the flue collector.

6. Disconnect flange nuts on Inlet/Outlet header,

loosen union(s) at gas pipe and slide heater away
from piping.

7. Lift heat exchanger straight up using caution not to

damage refractory.

8. Reverse above procedure to reinstall. Make sure

the insulation strips are properly replaced on top of
the refractory retainer.

PILOT

BURNER

BURNER

HOLD-DOWN

BRACKET

GAS
ORIFICE

GAS VALVE

BURNER TRAY REMOVAL -

ATMOSPHERIC MODELS

1. Shut off main electrical power switch to heater.
2. Shut off gas upstream of heater.
3. Remove front door.
4. Disconnect gas line from gas valve.
5. Remove (2) screws that mount burner tray to unit,

and (2) screws that secure gas valve to jacket.

6. Disconnect wires that terminate at gas valve.
7. Disconnect hi-tension wire from PC board.
8. Slide out burner tray.
9. Reverse above procedure to reinstall.

GAS VALVE REMOVAL -

ATMOSPHERIC MODELS

1. Shut off gas supply to the heater. Remove gas

piping to gas valve inlet.

2. Disconnect wires, pilot tubing and bleed line, if

required.

3. Remove burner tray from heater.
4. Turn vertical gas pipe from manifold slightly and

unscrew gas valve.

5. Reverse above procedure to reinstall.

MAIN BURNER AND ORIFICE REMOVAL -
ATMOSPHERIC MODELS

1. Remove burner tray.
2. Remove screws and burner hold-down bracket.

NOTE:

If the heat exchanger is sooted badly, the

burner hold-down bracket and spacer can become dis-
torted from direct-flame impingement and this usually
necessitates replacement of these parts.

3. Lift burners from slotted spacers and slide from ori-

fices. Clean with a wire brush.

4. Orifices usually do not need to be replaced. To

clean, run either copper wire or wood toothpick
through orifice. Do not enlarge hole. To remove
orifice, use a socket wrench and remove from
manifold. DO NOT overtighten when reinstalling.

HONEYWELL MILLIVOLT

PILOT

ROBERTSHAW MILLIVOLT

PILOT

206-406
Atmospheric

This manual is related to the following products: