Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

16

The P42 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft (3.7m) horizontal offset
using two 90

o

elbows (two 45

o

elbows equal one 90

o

elbow) with rigid pipe vent systems for

Propane and Natural Gas, as per the diagram below.

No Vent restrictor is required.

Vent must be supported at offsets

The P42 is approved for a 37 ft. (11.3m) straight
vertical, with rigid pipe vent systems for
Propane and Natural Gas, as per the diagram
below.

Vent restrictor #6 must be used

Diagram 3

Diagram 4

Note: Regency Direct Vent System (Flex) is only approved for

horizontal terminations.