Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

12

Rigid Pipe Adaptor

(Part# 510-994)

Pipe Length

Vertical

Terminal

Storm Collar

Part # 953

Flashing

943 or 943S

Ceiling Firestop

(Part # 963)

24" Pipe

Length

Adj.Pipe Length

11" - 14-5/8"

90 Elbow

o

Horizontal

Termination

Cap

Wall Thimble

Part # 942

Vinyl Siding

Standoff (Optional)

Part #950

RIGID PIPE VENTING

Horizontal or Vertical Terminations

The Rigid Pipe Venting System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are
offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P42.

The minimum components required for a basic
horizontal termination are:

1

Horizontal Termination Cap

1

90

o

Elbow

1

Flue Adaptor

1

Wall Thimble

1

Length of pipe to suit wall thickness
(see chart)

Alternate

Horizontal

Termination

Caps

INSTALLATION

When using piping other than Simpson

Dura-Vent, 3 screws must be used to

secure rigid pipe to adaptor.

Flat Wall Installation

Wall Thickness Vent Length

(inches) Required (inches)

4"

- 5-1/2"

6"

7"

- 8-1/2"

9"

10"

- 11-1/2"

12"

9"

- 14-1/2" 11" - 14-5/8" Adj. Pipe

15"

- 23-1/2"

17" - 24" Adj. Pipe

Corner Installation

Wall Thickness Vent Length
(inches) Required (inches)

3-1/4"

- 6-3/4"

11" - 14-5/8" Adj. Pipe

7-3/4"

- 16-1/4"

17" - 24" Adj. Pipe

7-1/4"

- 8-3/4"

6" + 12"

9" + 9"

4-1/4"

- 5-3/4"

6" + 9"

The FPI AstroCap

TM

and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent

GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPI

TM

, and FPI AstroCap

TM

are the proprietary trademarks of FPI

Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl
furring strips may be used, instead of the vinyl
siding standoff, to create a level surface to
mount the vent terminal. The Terminal must not
be recessed into siding. Measure the wall
thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside
surface of wall without siding and add 2 inches.

This product has been evaluated by Intertek for
using a Dura-Vent Flue Adaptor in conjunction
with Selkirk Direct-Temp and Ameri Vent Direct
venting systems. Use of these systems with
the Direct Vent GS starting collar is deemed
acceptable and does not affect the Intertek WHI
listing of components.

WARNING:

Do not combine venting components from
different venting systems.

However use of the the AstroCap

TM

and FPI

Riser is acceptable with all systems.