TOTAL POWER:
ZGL 683IT:
G20/G25 (2E+) 20/25
mbar = 9 kW
G30 (3+) 28-30 mbar =
654 g/h
G31 (3+) 37 mbar = 649g/
h
ZGL 643IT:
G20/G25 (2E+) 20/25
mbar = 8 kW
G30 (3+) 28-30 mbar =
567 g/h
G31 (3+) 37 mbar = 557
g/h
Electric supply:
230 V ~ 50 Hz
Category:
II2E+3+
Gas supply:
G20/G25 (2E+) 20/25
mbar
Appliance class:
3
By-pass diameters
Burner
Ø By-pass in 1/100 mm.
Auxiliary
28
Semi-rapid
32
Rapid
42
Triple Crown
56
Gas burners
BURNER
NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20/G25 20/25 mbar
LPG (Butane/Propane) G30/G31
28-30/37 mbar
kW
kW
inj. 1/100
mm
G20
G25
inj. 1/100
mm
G30
G31
m³/h
m³/h
g/h
g/h
Auxiliary
burner
1,0
0,33
70
0,095
0,111
50
73
71
Semi-rap-
id burner
2,0
0,45
96
0,190
0,221
71
145
143
Rapid
burner
3,0 (nat.
gas)
2,8 (LPG)
0,75
119
0,286
0,332
86
204
200
Triple
Crown
burner
4,0
1,4
146
0,381
0,443
98
291
286
Environment concerns
The symbol on the product or on its packaging
indicates that this product may not be treated as
household waste. Instead it should be taken to the
appropriate collection point for the recycling of electrical
and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential
negative consequences for the environment and human
health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed
information about recycling of this product, please contact
your local council, your household waste disposal service
or the shop where you purchased the product.
23