Regency C34 User Manual
Gas stoves, C34 freestanding direct vent gas stove, Back wall w all side wall side wall wall
C34 Freestanding Direct Vent Gas Stove
Gas Line In
J
C
I
H
Gas Line In
A
B
D
F
G
E
K
K
L
Back wall
W
all
Side
wall
Side
wall
Wall
N
M
P
P
O
O
Model
C34-NG3
C34-LP3
Fuel Type
Natural Gas
Propane
Minimum Supply Pressure
5.0” W.C. (1.25 kPa)
12.0” W.C. (3.00 kPa)
Manifold Pressure - High
3.82” W.C. (0.95 kPa)
11” W.C. (2.74 kPa)
Manifold Pressure - Low
1.1” W.C. (0.27 kPa)
2.9” W.C. (0.72 kPa)
Orifi ce Size
#36
#52
Minimum Input
16,000 BTU/h
16,000 BTU/h
Maximum Input
32,000 BTU/h
32,000 BTU/h
Vent Sizing
4” Inner / 6-5/8” Outer
4” Inner / 6-5/8” Outer
C34 Gas Stove
Dimension Description
C34
A
Unit Width
24” (610mm)
B
Unit Height
29-11/16” (737mm)
C
Unit Depth
21-5/8” (549mm)
D
Pedestal Height
11-3/4” (298mm)
E
Cast Leg Height
(including Bottom shield)
11-3/4” (298mm)
F
Bottom shield Height
4” (102mm)
G
Vent centerline to Side
12” (305mm)
H
Vent centerline to Back
7” (178mm)
I
Gas Line Height (from base)
9” (229mm)
J
Side to Gas Line
4-1/2” (114mm)
Alcove clearances
Dimension
Description
C34
K
Side Wall to Unit
10” (250mm)
L
Back Wall to Unit
6” (150mm)
M
Side wall to Vent Centerline
22” (559mm)
N
Back wall to Vent Centerline
13” (330mm)
Corner Clearances
Dimension
Description
C34
O
Wall to Unit Corner
1.5” (38mm)
P
Wall to vent centerline
14” (356mm)
Minimum ceiling height is 36" (914mm) from top of unit.
Minimum clearance to vent is 1-1/4” (32mm).
The above listed clearances are minimum distances to combustible
materials. When installing on carpet or vinyl fl ooring the bottom pedestal
cover plate must be installed.
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.
145
June 2007 Regency Product Specifi cations Book
Gas Stoves
Gas Sto
v
es