beautypg.com

Specifications – Rinnai RC80HPI User Manual

Page 3

background image

Manual - Rinnai Condensing Water Heaters

3

Specifications

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

Model

RC80HPi

RC80HPe

RC98HPi

RC98HPe

Minimum Gas Consumption Btu/h

9,500 for Natural Gas / 10,300 for Propane Gas

Maximum Gas Consumption Btu/h

157,000

199,000

Hot water capacity (Min - Max) *

0.4 - 8.0 GPM (1.5 - 30 L/min)

0.4 - 9.8 GPM (1.5 - 37 L/min)

Hot water capacity (45°F rise)

6.6 GPM (25 L/min)

8.5 GPM (32 L/min)

Default Temperature Setting (no controller)

120º F (49º C)

Temperature Controller Default Setting

104º F (40º C)

Maximum Temp Setting (commercial **)

185º F (85º C)

Maximum Temp Setting (residential)
see Temperature Ranges for more information

Selectable at 120º F (49º C) or at 140º F (60º C)

Minimum Temperature Setting

98º F (37º C)

Weight

63.9 lb (29 kg)

70.5 lb (32 kg)

Efficiency Rating

95.0%

Noise level

50 dB

Electrical
Consumption

Normal

63 W

44 W

80 W

59 W

Standby

2 W

Anti-frost Protection

220 W

172 W

220 W

172 W

By-Pass Control

Electronic

Minimum Gas Supply
Pressure

Natural Gas

5.0 inch W.C.

Propane

8.0 inch W.C.

Maximum Gas Supply
Pressure

Natural Gas

10.5 inch W.C.

Propane

13.5 inch W.C.

Type of Appliance

Condensing, Tankless, Temperature controlled continuous flow gas hot water system.

Operation

With or without remote controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.

Connections

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

Direct Electronic Ignition

Electric Connections

Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

Water Temperature Control

Simulation Feedforward and Feedback.

Water Supply Pressure

Minimum Water Pressure: 50 PSI (Recommended 60-80 PSI for maximum performance)

Maximum Water Supply Pressure

150 PSI

Remote Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

Energy Star Qualified

Yes

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

** for commercial and hydronic applications requiring higher temperatures

This manual is related to the following products: