beautypg.com

Flushing the heat exchanger (error code: lc or 00) – Rinnai RC80HPI User Manual

Page 16

background image

16

Manual - Rinnai Condensing Water Heaters

Flushing the Heat Exchanger (Error Code: LC or 00)

An “LC” or “00” error code indicates the unit is beginning to lime up and must be flushed. Failure to flush the
appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s
warranty. After flushing, reset the LC fault code by turning off the power to the unit and turning the power back
on.

Water Heater

Pressure Relief Valve

3/4" Ball Valve

3/4" Union

Check Valve

S

Pressure Regulator

Circulating Pump

Solenoid Valve

Boiler Drain Valve

KEY

Gas Supply

V1

V3

V2

V4

H1

H2

H3

Circulating Pump

Cold Water Line

Hot Water Line

n-line

Filter

I

1. Disconnect electrical power to the water heater.
2. Close the shutoff valves on both the hot water and

cold water lines (V3 and V4).

3. Connect pump outlet hose (H1) to the cold water

line at service valve V2.

4. Connect drain hose (H3) to service valve V1.
5. Pour 4 gallons of undiluted virgin, food grade,

white vinegar into pail.

6. Place the drain hose (H3) and the hose (H2) to

the pump inlet into the cleaning solution.

7. Open both service valves (V1 and V2) on the hot

water and cold water lines.

8. Operate the pump and allow the cleaning solution

to circulate through the water heater for 1 hour at
a rate of 4 gallons per minute (15.1 liters per
minute).

9. Turn off the pump.
10. Rinse the cleaning solution from the water heater

as follows:

a. Remove the free end of the drain hose (H3)

from the pail.

b. Close service valve, (V2), and open shutoff

valve, (V4). Do not open shutoff valve, (V3).

c. Allow water to flow through the water heater for

5 minutes

d. Close service valve, (V1), and open shutoff

valve, (V3).

11. Disconnect all hoses.
12. With (V4) closed, remove the in-line filter at the

cold water inlet and clean out any residue. Place
filter back into unit and open (V4).

13. Restore electrical power to the water heater.

Cleaning solution is 4 gallons of
undiluted virgin, food grade,
white vinegar.

This manual is related to the following products: