beautypg.com

Clearances from appliance, Attachment of the water heater – Rinnai RC80HPI User Manual

Page 18

background image

18

Manual - Rinnai Condensing Water Heaters

Clearances

from

Appliance

1. Identify the installation location and confirm that

the installation will meet all required clearances.

2. Securely attach the water heater to the wall using

any of the holes in the wall installation brackets
which are at the top and bottom of the water
heater. Ensure that the attachment strength is
sufficient to support the weight. Refer to the
weight of the water heater in the Specifications
section.

Attachment of the Water Heater

wall installation

brackets

to Com-

bustibles

to Non-

Combus-

tibles

Top of
Heater

12 inches
(305 mm)

2 inches
(51 mm)

Back of
Heater

0 (zero)

0 (zero)

Front of
Heater

6 inches
(152 mm)

6 inches
(152 mm)

Sides of
Heater

2 inches
(51 mm)

1/2 inch
(13 mm)

Floor/
Ground

12 inches
(305 mm)

2 inches
(51 mm)

Vent

4 inches * 0 (zero)

* 4 inches (102 mm) for enclosed area; 1 inch (26 mm) for unenclosed area.

The clearance for servicing is 24 inches in front of the water heater.

For closet installation: clearance is 6 inches (152 mm) from the front.

** 0 inches from vent components and condensate drain line.

to Com-

bustibles

to Non-

Combus-

tibles

Top of
Heater

12 inches
(305 mm)

2 inches
(51 mm)

Back of
Heater

0 (zero)

0 (zero)

Front
(Panel)

24 inches
(610 mm)

0 inches

(0 mm)

Sides of
Heater

6 inches

(152 mm)

1/8 inch

(3.2 mm)

Floor/
Ground

12 inches
(305 mm)

2 inches
(51 mm)

Front
(Exhaust)

24 inches
(610 mm)

24 inches
(610 mm)

RC80HPi, RC98HPi

RC80HPe, RC98HPe

to side

to front

to top

to floor/ground

This manual is related to the following products: