beautypg.com

Error codes, Warning – Rinnai RC80HPI User Manual

Page 13

background image

Manual - Rinnai Condensing Water Heaters

13

Error Codes

The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an error code
will flash on the Display of the temperature controller. This assists with diagnosing the fault and may enable you
to overcome a problem without a service call. Please identify the code displayed when inquiring about service.

Code

Fault

Remedy

03

Power interruption during
Bath Fill (Water will not flow
when power returns).

Turn off all hot water taps. Press ON/OFF twice.

10

Air Supply or Exhaust
Blockage

Ensure Rinnai approved venting materials are being used.
Check that nothing is blocking the flue inlet or exhaust.
Check all vent components for proper connections.
Ensure vent length is within limits.
Ensure condensation collar was installed correctly.
Verify dip switches are set properly.
Check fan for blockage.
Burner Sensor Error (see code 31)
Check the fins in the heat exchanger.

11

No Ignition

Check that the gas is turned on at the water heater, gas meter, or cylinder.
Ensure gas type and pressure is correct.
Ensure gas line, meter, and/or regulator is sized properly.
Bleed all air from gas lines.
Verify dip switches are set properly.
Ensure appliance is properly grounded.
Disconnect EZConnect™ or MSA controls to isolate the problem.
Ensure igniter is operational.
Check igniter wiring harness for damage.
Check gas solenoid valves for open or short circuits.
Remove burner cover and ensure all burners are properly seated.
Remove burner plate and inspect burner surface for condensation or debris.

12

Flame Failure

Check that the gas is turned on at the water heater and gas meter. Check for obstructions in

the flue outlet.

Ensure gas line, meter, and/or regulator is sized properly.
Ensure gas type and pressure is correct.
Bleed all air from gas lines.
Ensure proper Rinnai venting material was installed.
Ensure condensation collar was installed properly.
Ensure vent length is within limits.
Verify dip switches are set properly.
Ensure appliance is properly grounded.
Disconnect keypad.
Disconnect EZConnect™ or MSA controls to isolate the problem.
Check power supply for loose connections.
Check power supply for proper voltage and voltage drops.
Ensure flame rod wire is connected.
Check flame rod for carbon build-up.
Disconnect and reconnect all wiring harnesses on unit and PC board.
Check for DC shorts at components.
Check gas solenoid valves for open or short circuits.
Remove burner plate and inspect burner surface for condensation or debris.
Check the ground wire for the PC board.

14

Thermal Fuse

Check gas type of unit and ensure it matches gas type being used.
Check for restrictions in air flow around unit and vent terminal.
Check for low water flow in a circulating system causing short-cycling.
Ensure dip switches are set to the proper position.
Check for foreign materials in combustion chamber and/or exhaust piping.
Check heat exchanger for cracks and/or separations.
Check heat exchanger surface for hot spots which indicate blockage due to scale build-up.

Refer to instructions in manual for flushing heat exchanger.

Measure resistance of safety circuit.
Ensure high fire and low fire manifold pressure is correct.
Check for improper conversion of product.

Some of the checks below may need to be done by a qualified service technician. Call a
service technician for any remedy that involves gas or electricity. Call a service
technician if you have any doubt or reservation about performing the remedy yourself.

WARNING

This manual is related to the following products: