beautypg.com

Appendix a pin assignment – RAD Data comm MBE10-1D User Manual

Page 45

background image

A-1

Appendix A
Pin Assignment

This appendix:
• Provides information about the various interfaces and cable connections

supported by MBE.

Table A-1. Interface Signal List (Female Connectors)

Signal Function Source

V.24/
RS-232
DB-25
(Female)

V.35*
34-PIN
(Female)

EIA-530
DB-25
(Female)

V.36/
RS-449**
DB-37
(Female)

X.21***
DB-15
(Female)

Description

Pin Circuit

Pin Circuit Pin Circuit Pin Circuit

Protective
Ground

COMMON 1

A Frame

101

1 1 1

--

[SHIELD]

Chassis ground. May
be isolated from Signal
Ground.

Ground

Signal
Ground

COMMON 7

B Signal 102
GND

7 AB

19

SG 8

--

[GND]

Common Signal and
DC power supply
ground

Transmitted Data

DTE

2

S TD(B) 103
P TD(A) 103


2 BA(A)
14 BA(B)


2

T(A)

9 T(B)
[TRANSMIT]

Serial data output
from unit. The data
transitions must occur
on the rising edge of
the transmit clock.

Data

Received Data

DCE

3

R RD(A) 104
T RD(B) 104


6

RD(A)

24 RD(B)

4

R(A)

11 R(B)
[RECEIVE]

Serial data input to the
unit. The data
transitions occur on
the rising edge of the
clock.

Request to Send

DTE

4

C RTS

105

4

CA(A)

19 CA(B)

7 RS(A)
25 RS(B)

3

C(A)

10 C(B)
[CONTROL]

ON from the unit
upon completion of
self-test

Clear To Send

DCE

5

D CTS

106

5

CB(A)

13 CB(B)

9 CS(A)
27 CS(B)

--

Unit expects CTS ON

Data Set Ready

DCE

6

E DSR

107

6

CC(A)

22 CC(B)

11 DM(A)
29 DM(B)


-- Not

used

Data Terminal
Ready

DTE 20 H

DTR

108

20

CD(A)

23 CD(A)

12 TR(A)
30 TR(B)

--

ON when unit is ready
to transmit or receive
data

Control

Carrier Detect

DCE

8

F DCD 109

8

CF(A)

10 CF(B)


13 RR(A)
31 RR(B)

5

I(A)

12

I(B)

[INDICATION]

Unit expects DCD ON

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com