Chapter 2 Installation

MBE Family Installation and Operation Manual

2-8

Installation and Setup

POWER

O

I

AUI

TO V.35 LINE

100-230 VAC

Figure 2-5. MBE Rear Panel, V.35 Connector

POWER

POWER

O

O

I

I

TO RS-232/V.24

LINK 2 RS-232/V.24

LINK 1 RS-232/V.24

AUI

AUI

100-230 VAC

100-230 VAC

Figure 2-6. MBE Rear Panel, V.24 Connector

Connecting the Line

A connector is provided to connect each interface to the communication link.

To connect the line:
• See

Appendix A

for LINK connector pin assignments. Note that the X.21 and

V.36 connections are provided by adapter cables to the RS-530 (25-pin
connector) on the MBE rear panel.

Interface cards are interchangeable. Consult your RAD dealer for details.

Connecting the LAN

To connect to the LAN:
• Use a standard AUI (15-pin, D-type), 10Base2 (BNC) or 10BaseT (RJ-45)

connector, provided by RAD.

To ensure compliance with electromagnetic compatibility (EMC) requirements, it is

recommended that you only use shielded data cables with this product. Make sure
that the shield is connected to the metallic hood of the cable connector.

For units with V.35 ports, in order to protect against electrostatic discharge (ESD)
into the port, use a connector with an overlapping hood that completely covers
the pin connection.