RIGID PIPE VENTING SYSTEMS

BASIC HORIZONTAL & VERTICAL TERMINATIONS

Rigid Pipe Vent Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered in
decorative black, as well as galvanized fi nish.

The minimum components required for a basic
Horizontal Termination are:

1 AstroCap XL Termination Cap
1 90

o

Elbow

1 Rigid

Pipe

Adaptor

1 Wall

Thimble

1 Length of rigid pipe to suit wall thickness

The minimum components required for a basic
Vertical Termination are:

1 Vertical

Termination

Cap

1 Rigid

Pipe

Adaptor

1 Lengths of pipe to adequately
penetrate

roof

1 Ceiling

Firestop

1 Flashing
1 Storm

Collar

Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl furring
strips may be used, instead of the vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.

If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

The FPI AstroCap XL

TM

is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent Pro and Selkirk Direct-Temp.

AstroCap XL

TM

is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trade-

marks of Simpson Dura-Vent Co. Inc.

This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Simpson DV Pro, Metal-Fab Sure-Seal
and Selkirk Direct-Temp systems. Use of these
systems with the Rigid Pipe adaptor is deemed
acceptable and does not affect the Warnock
Hersey/Intertek listing of components.

WARNING:

Do not combine venting components from
different venting systems.

Exception: However, use of the the AstroCap
XL

TM

is acceptable with all systems.

INSTALLATION

Alternate

Horizontal Termination

Caps

Part # 5DT-ST14 (14")
Part # 5DT-ST36 (36")