beautypg.com

Installation, Framing & finishing, Inst alla tion – Regency Horizon HZ54 User Manual

Page 11

background image

HZ54 Regency Horizon

TM

Gas Fireplace

11

INST

ALLA

TION

INSTALLATION

Note: When constructing the framed opening, please ensure there

is access to install the gas lines when the unit is installed.

2) For exterior walls, insulate the enclosure to the same degree as the

rest of the house, apply vapour barrier and drywall, as per local instal-
lation codes. (Do not insulate the fi replace itself.)

WARNING: Failure to insulate and add vapor barriers to the inside
of the exterior wall will result in operational and performance
problems including, but not limited to: excessive condensation
on glass doors, poor fl ame package, carbon, blue fl ames etc.
These are not product related issues.

3) The unit does not have to be completely enclosed in a chase. You

must maintain clearances from the vent to combustible materials: See
"Clearances" section. Combustible materials can be laid against the
side and back standoffs and the stove base.

4) Non-combustible material (ie. tile, slate, etc) may be brought up to and

overlap the unit (top and bottom) ensuring that the maximum thickness
does not go beyond the 1-1/2" as shown in the diagram below. The
faceplate will not be able to be mounted if material is beyond 1-1/2".

FRAMING & FINISHING

1) Frame in the enclosure for the unit with framing material.

IMPORTANT: Header must be metal stud. All other framing may
be of combustible type such as 2x4 / 2x6 framing materials.

5) If material such as brick, stone, etc extends past the faceplate depth,

when fi nishing around the faceplate, the minimum opening dimen-
sions noted below must be adhered to ensuring for the removal of the
faceplate.