beautypg.com

Nortec NH Series User Manual

Page 24

background image

10-10

Page 17
2008-08-28

Table 4. Recommended Condensate Line at Distributor(s)

Dispersion Method

Condensate Hose

Copper Tube (Potable)

Stainless Steel Tube

(RO or DI)

1 x Steam Distributor

0.375 inch

NORTEC 132-8840

0.250 inch. MED-L Tubing

(0.375 inch OD)

0.375 Tube 0.049 inch thick

3 x Steam Distributor

0.375 inch

NORTEC 132-8840

0.500 inch. MED-L Tubing

(0.875 inch OD)

0.650 Tube 0.049 inch thick

Note: *When using more then 1 steam distributor, the condensate line must be trapped before it is
joined together. See figure 4

Table 5. Equivalent Lengths of Elbows and Tee Fittings

Nominal Tube

Diameter

Standard 90degree

Elbow

Standard 45 degree

Elbow Side

Outlet

Tee

0.750 / 0.875 in.

2 ft.

1 ft.

4 ft.

1.500 / 1.750 in.

3 ft. 6 in.

1ft. 9 in.

7 ft.

2.000 / 2.500 in.

4 ft. 6 in.

2 ft. 3 in.

10 ft.

Table 6. Humidifier and Distributor Inlet/Outlet Sizes

Humidifier

Steam Outlet

Distributor

Steam Inlet

NH 5-30

0.875 in. OD

ASD, BSD

0.875 inch OD

NH 50-100

1.75 in. OD

CSD

1.75 inch OD

NH 150-200

Two 1.75 in. OD

Blower Pack

0.875 inch OD or

1.75 inch OD

SAM-e

1.75 inch OD*

mini SAM-e

0.875 or 1.75 inch OD**

NOTE: * SAM-e may have multiple 1.75 in. inlets depending on order.

** mini SAM-e inlet is determined on order and may have two 1.75 in. OD inlets.