Fault rectification – STIEBEL ELTRON SHZ 100 LCD User Manual
Page 18

18
6. Fault rectification
by the user
No hot water.
No voltage
.
heck fuses in the house installation
.
Fault
Info
Rectification
Table 2
Water heating continues
(
see Table 3
).
Clean and/or descale the outlet fittings
.
No flow rate
.
Dirt or limescale in the perlators in the
fittings or shower heads
.
Service symbol
appears.
No water heating
(
see Table 3
).
Service/maintenance is required
.
Defect
symbol
flashing
.
7. Fault rectification
by the qualified installer
Corrective maintenance urgently required;
inform qualified installer
.
Fault / defect code / Info
Possible cause / defect
Rectification
Table 3
Water heating continues.Maintenance
requirement
.
Service code enquiry.
Service / maintenance required
.
Temperature sensor fault
.
Temperature sensor fault
.
Parasitic current anode fault
.
Communication fault with electronic
„regulator“ and „control unit“ modules
.
Check that connector „X10“ is correctly
fitted
L
.
Inspect temperature sensor.
Check that connector „X10“ is correctly
fitted
L
.
Inspect temperature sensor.
Check that connector „X7“ is correctly
fitted
L
.
Check parasitic current anode and
wiring
.
No water heating
.
Defect code enquiry.
Corrective maintenance urgently required!
Defect symbol
>>
flashing
.
Temperature sensor defective
.
Safety thermal cut-out (STB) actuated
.
Heating element defective
.
Check that connector „X10“ is correctly
fitted
L
.
Inspect temperature sensor
.
Ursache beheben und entriegeln; STB kon-
trollieren ggf. austauschen.
Rectify cause and unlock; inspect STB and if
necessary replace
.
Fill the reservoir with water
.
No water in the reservoir
.
No anode current
.
Check that connector „X7“ is correctly
fitted
L
.
Inspect parasitic current anode
and wiring
.
Replace regulator electronic module
(22).
Service symbol.
Check that connector „X2“ is correctly
fitted on both modules
H
.
Check connection cable and modules
.
Code
Continuous display -
setpoint temperature.
Code
Continuous display -
outlet temperature
.
Code
No anode protection
.
Code
Last preset setpoint values
active. Possibly continuous
display of
.
Code
Continuous display -
setpoint temperature
.
Code
No display of heating
element symbol
.
Code
Running dry protection
.
Restore voltage supply
.
No voltage
.
No display in the control panel
.
No connection to the control unit
.
Control unit defective
.
Check that connector „X2“ is correctly
fitted
H
.
Check control unit (
20
) and if necessary
replace
.
Code
Relay defective
.