Analog voice module specifications – Nx Networks 3000 User Manual
Page 59

3000 Series User Guide
45
Analog Voice Module Specifications
The following table lists the specifications for the analog voice module.
Agency Approvals
EMI—
FCC Part 15 Class A;
CISPR 22 Class A; EN55022
Telecom— FCC Part 68, CS03, CTR2,
I-CTR3, CTR 12/A1, CTR13
Safety—
UL 1950, CSA 22.2, TS.001,
AS/NZS3260, EN60950 CB
scheme for all countries
Immunity—IEC 801-2, 801-3, 801-4
Interface Types
•
Two-wire FXS loop/start
•
Two-wire FXO loop/ground start and two-wire
FXS loop/start
•
Two-wire FXO loop/ground start
•
Two- or four-wire E & M type I, II, and V
Dialing
DTMF or pulse (10 or 20 pps)
Co-processor
MPC850, 50 MHz
Signalling
Wink start, delay dial, immediate start, hoot and holler,
and phone
Indicator