beautypg.com

N-Tron Ntron 7014FX2 User Manual

Page 66

background image

6/28/2007 page 66 of 145

In rare cases an N-Ring can have a “Partial Fault”. An example of this is to have a break in just one fiber in
a duplex channel fiber pair. The screenshot below shows N-Ring Manager Status when a ‘Higher’ N-Ring
Port (GB2 or FX2) is not receiving self health frames all the way around the N-Ring, though the other (low
GB1/FX1) N-Ring port is:

N-Ring Partial Fault (GB2 is not receiving self health from GB1)

N-Ring Status View

Switch is an N-Ring Manager, using N-Ring Aging Time = 20 seconds

Refresh every

6

secs.

Update

Pause

Print...

0 Active Members Detected In Current N-Ring (0 reporting)

Switch No MAC Address

IP Address

Subnet Mask Name

Ports

RM

00:07:af:00:b1:40

192.168.1.135 255.255.255.0 N-TRON Switch

GB2
GB1


The screenshot below shows N-Ring Manager Status when a ‘Lower’ N-Ring Port (GB1 or FX1) is not
receiving self health frames all the way around the N-Ring, though the other (high GB2/FX2) N-Ring port
is:

N-Ring Partial Fault (GB1 is not receiving self health from GB2)

N-Ring Status View

Switch is an N-Ring Manager, using N-Ring Aging Time = 20 seconds

Refresh every

6

secs.

Update

Pause

Print...

0 Active Members Detected In Current N-Ring (0 reporting)

Switch No MAC Address

IP Address

Subnet Mask Name

Ports

RM

00:07:af:00:b1:40

192.168.1.135 255.255.255.0 N-TRON Switch

GB2
GB1

This manual is related to the following products: