beautypg.com

Table 3-2. fused power output ratings, E 3-2 l – National Instruments Module NI PXI-8250 User Manual

Page 24

background image

Chapter 3

Hardware Overview

NI PXI-8250 User Manual

3-8

ni.com

The NI PXI-8250 has self-resetting fuses rated at 1 A/125 V on the front
end and one-blow fuses rated at 4 A/125 V on the back end of the card to
protect the card from excessive current draw. Refer to Figure 3-1 for the
locations of these fuses.

When current is exceeded on any of the rails (the current limits are provided
in Table 3-2), the self-resetting fuses will open the circuit. These fuses are
designed to reset themselves and do not need to be repaired.

As a fail-safe, one blow fuses have also been added to ensure that excessive
current is stopped if a self-resetting fuse fails to operate properly. In the
event that any of the one-blow fuses blow, the board must be returned for
repair.

Table 3-2. Fused Power Output Ratings

Voltage Rail

Maximum Allowed Current Draw

+5.0 V

0.75 A

+3.3 V

0.75 A

+12.0 V

0.25 A

–12.0 V

0.25 A