beautypg.com

Nortel Networks COMMUNICATION SERVER 1000 NN43021-110 User Manual

Page 44

background image

44

System architecture

IPE is associated with network loops. IPE cards are supported by NT8D04
Superloop Network Card loops. The traffic requirements of all IPE cards
provisioned on a particular network loop must match the traffic capacity
of that loop.

IPE includes:

controller cards that provide timing and control sequences and
monitoring capabilities

analog and digital line and trunk cards that provide interfaces to
equipment outside the modules (such as telephones, data terminals,
and trunks)

Table 5 "Intelligent Peripheral Equipment cards" (page 44)

lists the IPE

cards and the number of terminations each supports.

Table 5
Intelligent Peripheral Equipment cards

Intelligent Peripheral Equipment cards

Number of

terminations

Controller cards:

NT8D01 Controller Card-4

N/A

NT8D01 Controller Card-2

N/A

Line cards:

NT1R20 OPS Analog Line card

8

NT5K02 Analog Line card

16

NT5K96 Analog Line card

16

NT8D02 Digital Line card

16 to 32

NT8D09 Analog Message Waiting Line card

16

Trunk cards:

NT5K07 Universal Trunk card

8

NT5K17 Direct Dial Inward Trunk card

8

NT5K18 Extended CO Trunk card

8

NT5K19 E&M/2280 Hz Trunk card

4

NT5K36 Direct Inward/Direct Outward Dial card

4

NT5K70 Extended CO Trunk card

8

Note: Terminal number (TN) density per segment is 16 to 128 TNs, with 64
to 512 TNs per IPE module. The maximum TN density assumes all slots
are equipped with NT8D02 Digital Line cards with 16 voice and 16 data TNs
provisioned. A typical mix of line and trunk cards yields a nominal density of 64
TNs per segment, 256 TNs per IPE module.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Large System Overview

NN43021-110

02.05

Standard

30 September 2008

Copyright © 2003-2008 Nortel Networks

.