1. Carefully remove the glass door and all logs. (Refer to
the installation manual)
2. Remove the two screws holding the front portion of the
rear air defl ector
. Remove the pilot shield by removing the
two screws as illustrated. (Fig. 42)
3. Remove the 3 screws holding
the burner down and carefully
remove the burner. (Fig. 43)
4. Install t
he right brick panel by sliding the bottom edge of
the panel down the right fi rebox side then pivot the top e
dge
of the panel into place against the fi rebox wall. Hold in place
with the brick retainers. (Fig. 44)
Note: Due to the brittle material of the bricks, care must
be taken not to bend or force them into place.
Note: Refractory panels require a 24 hour curing period
on a low fl ame.
3
2
1
HERRINGBONE PATTERN ILLUSTRATED
When shipped, the brick panels range in varying shades of
tan. During initial use, the panels will emit a slight odor for
a few hours. This is a normal condition that will not occur
again. Simply open a window to suffi ciently ventilate the
room. The appearance of the panels will permanently
lighten in colour with use.
STEP
#3
5. Rest the bottom edge of the rear panel on top
of the rear portion of the air defl ector at the back of
the fi
rebox and push into place. The rear panel is
held in place when both side panels are in position.
6. Install
the left brick panel us
ing the same method
described in step 4.
7. Replace the burner, air defl ector, logs and glass door.
STEP
#2
PILOT SHIELD
DECORATIVE BRICK PANEL INSTALLATION
FIGURE 42
FIGURE 43
FIGURE 44
FIGURE 45