Setting time server – NEC SIGMABLADE N8406-020 User Manual
Page 142

- 142 -
4.
Set the time of the built-in clock by using the "date" command.
HW060000955:admin> date "0627220706"
Wed Junv 27 22:07:00 Localtime 2006
HW060000955:admin>
Command parameters:
date "mmddhhmmyy"
Parameters:mm = Month (00 – 12)
dd = Date (00 – 31)
hh = Hour (00 – 23)
mm = Minute (00 – 59)
yy = Lower two digits of dominical year (00 - 99)
Setting Time Server
1.
Type "tsclockserver" on the console screen.
Any commands used on the switch console should be specified with
lowercase letters.
2.
Check the current setting of the time server.
HW060000955:admin> tsclockserver
LOCL
HW060000955:admin>
"LOCL" appears if the time server is not set.
3.
Set the time server by using the "tsclockserver" command on the console screen.
Type "tsclockserver xxx.xxx.xxx.xxx" to set the time server.
Value "xxx.xxx.xxx.xxx" is the IP address of the time server to be set.
HW060000951:admin> tsclockserver 192.168.1.1
Updating Clock Server configuration...done.
HW060000951:admin>
For the IP address of an available time server, contact your system
administrator.
4.
After setting, type "tsclockserver" on the console screen to check the setting.
HW060000951:admin> tsclockserver
192.168.1.1
HW060000951:admin>
The IP address of the time server being set appears.