Using the Scanner: Using the SF-200 Slide Feeder
Click the double right-arrow button in the attachment utility to
move the feed mechanism to where it is fully visible. If you
move the feed mechanism too far, click the left-arrow button to
move it back. The single-arrow buttons can be used for fine
adjustments. Once the feed mechanism is visible, insert the
pegs on the attachment into the holes in the feed mechanism.
✔
Caution:
Be sure that the attachment is securely in place.
If the attachment is loose, slides may not feed properly and dam-
age to the SF-200 could result.
Click the OK button in the attachment utility window to return
the feed mechanism to its initial position. You are now ready
to begin scanning.
When scanning slides with flat mounts or slides less than 2 mm
thick, you will need to remove the attachment. Use the attach-
ment utility as described above to move the feed mechanism
into the magazine, then remove the attachment and click OK to
return the feed mechanism to its initial position.
What to do if the feeder jams
If a jam occurs, open the magazine cover and remove the slides
remaining in the feed and eject magazines. Pull back the feed
push-plate and hook it in the notch so that it does not spring
back to its original position.
The method for resolving a jam depends on the position of the
feed mechanism when the jam occurred. If the jammed slide is
visible in the magazine and the feed mechanism has returned to
its housing in the front of the unit, the jammed slide can be
removed with your fingers. If the feed mechanism has locked
while feeding a slide, you will need to use the attachment utility
to resolve the jam (the attachment utility is a special program
for the SF-200 distributed with the Nikon Scan software that
came with your scanner).