beautypg.com

Figure 5. ni 6509 signal connections, Protecting inductive loads – National Instruments NI 6509 User Manual

Page 16

background image

NI 6509 User Guide and Specifications

16

ni.com

Figure 5. NI 6509 Signal Connections

Protecting Inductive Loads

When inductive loads are connected to outputs, a large
counter-electromotive force may occur at switching time because of the
energy stored in the inductive load. These flyback voltages can damage
the outputs and/or the power supply.

To limit these flyback voltages at the inductive load, install a flyback diode
across the inductive load. For best results, mount the flyback diode within
18 inches of the load. Figure 6 shows an example of using an external
flyback diode to protect inductive loads.

41

43

45

47

67

69

71

73

50, 100

NI 6509

+5 V

+5 V

LED

Port 7

P7<7..4>

Port 0

P0<3..0>

GND

TTL Signal